A value of RSET and RL is prescribed with the data sheet of ADV7341 as follows .
For low-drive operation, RSET1 must have a value of 4.12 kΩ, and RL must have a value of 300 Ω.
For full-drive operation, RSET1 must have a value of 510 Ω, and RL must have a value of 37.5 Ω.
Can't a setup of those other than this be performed?
When I cannot set it, please tell me the reason.
When you can set it, which value can you use?
When I set it in a value of Low-drive mode, it becomes the wave pattern of the blue of the attached file.
Is there the probable cause?
Is it not output like Figure 70-a of data sheet p65?
Regards
Yuji